å‚è§é™„ä»¶(1892KB,3页)。
[摘è¦]目的:测定å‰ç‰™çƒ¤ç“·ä¿®å¤å† ã€æ¡¥çš„疲劳寿命。方法:制作å‰ç‰™çƒ¤ç“·å† ã€æ¡¥è¯•ä»¶å„3个进行疲劳寿命测定,分别在实验进行0hã€16hã€48hã€80hã€160h时,用体视显微镜下咬åˆéƒ¨ä½ç“·å±‚表é¢çжæ€ï¼Œè‡³320håŽå®žéªŒç»“æŸï¼Œåœ¨æ‰«æç”µé•œä¸‹è§‚察。结果:å„ç»„çƒ¤ç“·å† ã€æ¡¥ä½“凿œªå‡ºçŽ°æ˜Žæ˜¾çš„ç“·å´©è£‚çŽ°è±¡ï¼Œä½†åœ¨å’¬åˆéƒ¨ä½åŠå…¶é™„è¿‘å‡å‡ºçްä¸åŒç¨‹åº¦çš„微裂隙(列å¸å°äºŽ20μm)。结论:å‰ç‰™çƒ¤ç“·ä¿®å¤ä½“ä¸ä»…具有良好的美å¦ç‰¹æ€§ï¼Œè€Œä¸”也具有相当优良的抗疲劳特性。
[关键è¯]å‰ç‰™ï¼›çƒ¤ç“·ï¼›å† ;桥;疲劳寿命;疲劳性磨耗
[ä¸å›¾åˆ†ç±»å·]R783 [æ–‡çŒ®æ ‡è¯†ç ]A [æ–‡ç« ç¼–å·]1008-6455(2011)05-0831-03
Measuring the fatigue life of porcelain fused metal crown and bridge of anterior teeth
LI Ming-yong1,MA Xuan-xiang2,LI Yu-long3,SUO Tao3,LI Hao-ping1,MENG Yuan1,HUO Li1,LIU Fang-xia1
(1.Department of Stomatology, No. 451 Hospital of PLA, Xi'an 710054, Shaanxi,China;2. School of Stomatology,The Fourth Military Medical University;3. Aviation Institute, Northwestern Polytechnical University)
Abstract:ObjectiveTo measure the fatigue life of porcelain fused metal (PFM) crown and bridgeof anterior teeth.MethodsPFM crown and bridge of anterior teeth were made for measurement of its fatigue life. The surface of porcelain on bitting area were observed by stereoscopic zoom microscopes after 0hã€16hã€48hã€80hã€160h, and by scaning electric microscopes(SEM) after 320h.ResultsEach PFM crown and bridge of anterior teeth had no procelain cracks in evidence after experiment, however there are some microscopic wears by SEM (under 20μm).ConclusionPFM restorationsof anterior teeth have not only esthetics capability but also rather fine anti-fatigue characteristic.
Key words:anterior teeth;porcelain fused to metal(PFM);crown;bridge;fatigue life;fatigue wear
å‰ç‰™çš„大é¢ç§¯ç¼ºæŸã€ä¸¥é‡å˜è‰²ä¸€èˆ¬é€‰æ‹©çƒ¤ç“·å† ã€æ¡¥ä¿®å¤ã€‚由于å‰ç‰™çš„ç¾Žè§‚è¦æ±‚较高,å£è…”医å¦å·¥ä½œè€…多把注æ„力集ä¸äºŽå…¶è‰²å½©å’Œå½¢æ€çš„ç ”ç©¶ä¸Š[1-2]ï¼Œè€Œå¯¹å…¶åŠ›å¦æ€§èƒ½å…³æ³¨è¾ƒå°‘ã€‚æœ¬å®žéªŒçš„ç›®çš„æ˜¯é€šè¿‡è‡ªè¡Œç ”åˆ¶çš„å£è…”ä¿®å¤ä½“疲劳寿命测试机对å‰ç‰™çƒ¤ç“·å† ã€æ¡¥çš„疲劳寿命进行测定,以全é¢è®¤è¯†å‰ç‰™çƒ¤ç“·ä¿®å¤ä½“çš„å„项性能。
1ææ–™å’Œæ–¹æ³•
1.1 å®žéªŒè®¾å¤‡ã€ææ–™ï¼šå£è…”疲劳测试试件选用å‰ç‰™å•å† åŸºç‰™æ¨¡åž‹å’Œå‰ç‰™æ¡¥åŸºç‰™æ¨¡åž‹ã€å¯¹åº”下颌选用å‰ç‰™æ¡¥åŸºç‰™æ¨¡åž‹[3]ã€å£è…”ä¿®å¤ä½“疲劳寿命测试机[4](è‡ªè¡Œç ”åˆ¶)ã€YD-15动æ€ç”µé˜»åº”å˜ä»ª(åŽä¸œç”µå仪器厂)ã€Micro-measurements Division EP-08-031DE-120应å˜ç‰‡(Measurement Group Inc. ,U.S.A )4å¼ ã€Tektronic K420示波器(Tektronic Inc.,U.S.A)ã€Nikon SMZ800体视显微镜(Nikon Inc.,Japan),Jeol JSM-5800扫æç”µé•œ(Jeol electric Ltd.,Japan)。
1.2 方法
1.2.1 在选用的下å‰ç‰™æ¡¥åŸºç‰™æ¨¡åž‹ä¸Šåˆ¶ä½œC1-D2é‡‘å±žé“¸é€ æ¡¥1个,基牙å•å† åŽšåº¦0.5~1.0mm,形æ€ç”¨æ ‡å‡†æ¨¡åž‹çš„å‰ç‰™èœ¡åž‹ç¿»åˆ¶ï¼›å†ç”¨ä¸Šå‰ç‰™å•å† åŸºç‰™æ¨¡åž‹å’Œå‰ç‰™æ¡¥åŸºç‰™æ¨¡åž‹åˆ¶ä½œç›¸å¯¹åº”çš„B区ä¸åˆ‡ç‰™çƒ¤ç“·å† ã€B区ä¸åˆ‡ç‰™ç¼ºå¤±çš„三å•ä½A1-B2烤瓷桥,å•å† å’Œæ¡¥å›ºä½ä½“é‡‘å±žåŸºåº•å† åŽš0.3~0.4mm,烤瓷层厚度1.0~2.0mm[5],与临床实际情况相符。共2组,æ¯ç»„å„3个。
1.2.2用薄咬åˆçº¸å¯¹ä¸Šã€ä¸‹é¢Œè¯•ä»¶ä¸Šçš„çƒ¤ç“·å† ã€æ¡¥å’Œå¯¹åˆçš„金属桥进行调牙åˆ[6]ï¼Œä½¿çƒ¤ç“·å† ä¸Šåˆ‡ç‰™çš„èˆŒé¢åˆ‡1/3处与金属桥D1-2下切牙的唇é¢åˆ‡ç«¯æœ‰å‡åŒ€çš„ã€å¯†åˆ‡çš„æŽ¥è§¦ï¼›çƒ¤ç“·æ¡¥çš„åŒä¾§åŸºç‰™å›ºä½ä½“ä¸Žå¯¹ç‰™åˆæ— å’¬åˆæŽ¥è§¦ï¼Œè€Œæ¡¥ä½“ä¸»è¦åŠŸèƒ½åŒºèˆŒé¢åˆ‡1/3处与对牙åˆç›¸åº”部ä½é‡‘属桥D1-2下切牙的唇é¢åˆ‡ç«¯å‡åŒ€ã€å¯†åˆ‡æŽ¥è§¦ã€‚调牙åˆåŽä¸Šé‡‰ï¼Œç£·é…¸é”Œæ°´é—¨æ±€ç²˜å›ºã€‚
1 ......