回到顶部
2024-12-12当å‰ä½ç½®ï¼šç½‘站首页 > è¡Œä¸šåŠ¨æ€ > æ•°æ®å…±äº« > 期刊æ‚å¿— >

论文下载:ä¸åŒçŽ¯å¢ƒæ¡ä»¶ä¸‹åŒä¸€è‰²æ ‡çš„æ•°ç è‰²åº¦å€¼ä¹‹é—´çš„相互关系

第1页
 å‚è§é™„件。

  [摘è¦] 目的 研究åŒä¸€è‰²æ ‡åœ¨ä¸åŒçŽ¯å¢ƒæ¡ä»¶ä¸‹æ‹æ‘„的数ç è‰²åº¦å€¼ä¹‹é—´çš„å˜åŒ–规律。 方法 å…ˆåœ¨æš—æˆ¿ä¸­æ‹æ‘„Vita 16色比色æ¿å„色片并输入Abode Photoshop CS软件,采集å„è‰²ç‰‡è‰²åº¦å€¼åˆ¶ä½œæˆæ ‡å‡†æ•°æ®åº“,然åŽé€‰æ‹©ç™½å¤©æ²¡æœ‰é˜³å…‰ç›´å°„的背光诊室和关闭普通窗帘的白天诊室,将A2è‰²ç‰‡ä¸Žå…¶ä»–è‰²ç‰‡å¹¶æŽ’å¯¹ç§°åœ¨ä¸€èµ·æ‹æ‘„,æ¯å¼ ç…§ç‰‡è¾“入软件åŽè°ƒæ•´å…¶ä¸­A2色片的色度值到标准数æ®åº“中A2è‰²ç‰‡çš„è‰²åº¦å€¼ï¼Œæ£€éªŒå¹¶æŽ’æ‹æ‘„的色片的色度值与标准数æ®åº“中åŒè‰²å·è‰²ç‰‡çš„色度值之间的色差。 结果 16色比色æ¿ä¸­å„实验组色片ç»è¿‡è½¯ä»¶è°ƒæ•´æœ‰63.89%的色片色差值≤2,有82.78%的色片色差值≤4。 结论 åªè¦æ•°ç ç›¸æœºæ€§èƒ½ç¨³å®šï¼Œè®¾ç½®ä¿æŒä¸å˜ï¼Œå…‰æºäº®åº¦è¶³å¤Ÿï¼Œå…¶æ‰€æ‹æ‘„的色片数ç è‰²åº¦å€¼åŸºæœ¬ç¨³å®šï¼Œé€šè¿‡è½¯ä»¶è°ƒæ•´è‰²å·®åœ¨è‚‰çœ¼ä¸å¯å¯Ÿè§‰çš„æœ‰63.89%ï¼Œè‰²å·®åœ¨ä¸´åºŠå¯æŽ¥å—的范围的达82.78%。

 [关键è¯] æ¯”è‰²ï¼›æ•°å­—åŒ–æ¯”è‰²ï¼›æ•°ç æ‘„影;色度值

 [中图分类å·] R318.6 [文献标识ç ] A [文章编å·] 1673-7210(2012)02(b)-0096-03

 The interrelations of digital colorimetric values of the same shade tab obtained in different environments

 WEI Bin XU Min CHEN Ling

 Department of Stomatology, the First Affiliated Hospital of Fujian Medical University, Fujian Province, Fuzhou 350005, China

 [Abstract] Objective To investigate the interrelations of digital colorimetric (CIE) values of the same shade tab obtained in different environments. Methods First, the image of each shade tab of Vita 16 color shade guide was taken by a digital camera in the dark room and entered Abode Photoshop CS software. The CIE values of all shade tabs were collected and form a standard database. Then, in the daytime, in the clinic without direct sunlight with curtain close, placed A2 shade tab and each other shade tab symmetrically in the line and took photographs. After inputting each photograph, the CIE value of A2 shade tab was modified to its corresponding value in standard database. The difference between CIE value of each other shade tab in the photo and their corresponding value in standard database was assessed. Results After modified by using software, of 16 shade tabs, 63.89% of them whose color difference value was ≤ 2, and 82.78% of them whose color difference value was ≤ 4. Conclusion As long as the performance of camera is stable, setting keeps the same and light resource is bright enough, the CIE values of shade tabs can be stable. After modified by using software, color difference which could not perceived by naked eyes is 63.89%. Color difference which could be acceptable in clinical practice is 82.78%.

 [Key words] Color matching; Digital color matching; Digital photography; Colorimetric values

 å£è…”ä¸´åºŠç‰™è‰²é‡‡é›†ç›®å‰æœ‰ä¸¤ç§æ–¹å¼ï¼šè‚‰çœ¼æ¯”è‰²æ³•å’Œä»ªå™¨æ¯”è‰²æ³•ã€‚é‡‡ç”¨è‚‰çœ¼æ¯”è‰²ï¼Œå¾ˆå¤šå› ç´ ä¼šå½±å“æ¯”色的准确性,ä¸åŒçŽ¯å¢ƒæ¡ä»¶ä¼šå¾—出ä¸åŒçš„颜色。使用仪器比色相对稳定 ......
上一篇:1例获得性血å‹ç—…的护ç†ä½“会(病例报告)
下一篇:论文下载:å¥è„¾ç›Šè‚¾æ´»è¡€ä¸­è¯å¯¹æ—©æœŸ2型糖尿病肾病的临床疗效分æž
Copyright © 2012-2024. All rights reserved  å¤‡æ¡ˆå·ï¼šäº¬ICP备06040839å·-8  XML地图  æ¨¡æ¿å·´å·´
è¡Œä¸šåŠ¨æ€ | 生活ä¿å¥ | ä¸­åŒ»ä¸­è¯ | 美容天地

扫ç å…³æ³¨å…¬ä¼—å·