  [摘è¦]目的:分æžä¸åŒæ–½åŠ›æ—¶é—´å¯¹å¾®ä¸é”ˆé’¢ç§æ¤æ”¯æŠ—稳定性的影å“。方法:选择20例错牙åˆç•¸å½¢æ‚£è€…(ç”·10例,女10例),年龄16~18å²ï¼Œåˆ†åˆ«å°†ç§æ¤é’‰è¢«æ¤å…¥æ¯ä½æ‚£è€…上颌两侧第一å‰ç£¨ç‰™å’Œç¬¬ä¸€ç£¨ç‰™åŒºä½œä¸ºç§æ¤é’‰æ”¯æŠ—内收å‰ç‰™,å…±æ¤å…¥40颗ä¸é”ˆé’¢ç§æ¤é’‰ã€‚男女患者按加载时间ä¸åŒè¢«éšæœºå¹³åˆ†ä¸ºä¸¤ç»„ï¼Œå®žéªŒç»„1ï¼šç§æ¤é’‰æ¤å…¥åŽä¾¿é‡‡ç”¨é•钛拉簧å³åˆ»åŠ åŠ›ï¼Œå®žéªŒç»„2:4周åŽåœ¨è¿›è¡ŒåŠ åŠ›,分别通过头颅侧ä½ç‰‡æµ‹é‡ç§æ¤é’‰åŠ è½½å‰åŽåŠå¹´çš„ä½ç§»å˜åŒ–。然åŽå¯¹ä¸¤ä¸ªå®žéªŒç»„进行统计学分æžã€‚结果:实验组1ï¼šç§æ¤é’‰åœ¨çŸ¢çжå‘上平å‡ç§»åŠ¨äº†1.31mm,垂直å‘上平å‡ç§»åŠ¨äº†1.53mm。实验组2ï¼šç§æ¤é’‰åœ¨çŸ¢çжå‘和垂直å‘的平å‡ä½ç§»æ˜¯0.83mmå’Œ1.03mm。结论:ä¸é”ˆé’¢ç§æ¤é’‰èƒ½å¤Ÿä¸ºå†…æ”¶å‰ç‰™æä¾›ç¨³å®šå’Œå¯é çš„æ”¯æŠ—,æ¤å…¥4周åŽå†æ–½åŠ›æ›´æœ‰åŠ©äºŽç§æ¤é’‰çš„稳定。

 [关键è¯]ä¸é”ˆé’¢ï¼›å¾®ç§æ¤ä½“;稳定性

 [中图分类å·]R783.5 [文献标识ç ]A [文章编å·]1008-6455(2011)10-1617-03

 Study on the stability of stainless miniscrew used as orthodontic anchorage

 LI Yong-feng,XIAO Xuan-dui,HE Zhan-feng,WANG Chao-yan,SUN Xiao-ai

 (Department of Stomatology,Chang'an Hospital,Xi'an 710018,Shaanxi,China)

 Abstract:ObjectiveTo study the stability of stainless steel implant used as anchorage under different force time.MethodsTwenty malocclusional patients(10males,10females average age 16~18 years old)with a total forty miniscrews were examined.Miniscrews were insered on the maxillary tooth-bearing area between the second bicuspid and the first molar as a direct anchorage for anterior teeth extraction.All the patients were divided into 2 groups.Force was activated immediately by nickel-titanium coil springs in group 1 after the insertion of the mini-screws.After 4 weeks the force was applied in group 2.the distance about the movement of the forced miniscrew were mearsured by the cephalometric radiographs at the beginning and half year later.ResultsIn group 1,the miniscrews were tipped vertically 1.53mm and the sagittal distance of movement was 1.31mm on average.In group 2,the distance was 0.83mm sagittally and 1.03mm vertically.Conclusion The stainless steel miniscrew could provide enough anchorage control for anterior teeth extraction. It is more stable for force exertion on after 4 weeks.

 Key words:stainless steel;miniscrew implant;stability

 ç”±äºŽç§æ¤ä½“支抗æ’定,无需患者é…åˆå°±èƒ½èŽ·å¾—ç†æƒ³çš„æ²»ç–—效果等诸优点,目å‰è¢«ä¸´åºŠä¸Šå¹¿æ³›åº”用。当å‰ä¸´åºŠä¸Šä¸»è¦åº”ç”¨çš„ç§æ¤ä½“支抗大体å¯ä»¥åˆ†ä¸ºç‰™ç§æ¤ä½“ã€å¾®åž‹é’›æ¿ï¼Œå¾®ç§æ¤é’‰[1]3ç§ï¼Œå…¶ä¸­å¾®åž‹ç§æ¤é’‰åœ¨å…¶ä¸­å› ä½“积å°ã€åˆ›ä¼¤å°ã€æ˜“于æ¤å…¥å’Œå–出,æ¤å…¥åŽåŠ è½½æ—¶é—´æ—©ï¼Œæ¤å…¥ä½ç½®è¾ƒå¤šå’Œæ¤å…¥æ–¹æ³•简å•而被临床医师广为采用。

 å¾®ç§æ¤é’‰æ”¯æŠ—虽然因其体积å°è€Œå­˜åœ¨ä¸€ç³»åˆ—çš„ä¼—å¤šä¼˜åŠ¿ï¼Œä¸Žæ­¤åŒæ—¶ç¨³å®šæ€§ä¾¿æˆä¸ºä¸´åºŠä¸­æ¯”较关心的è¯é¢˜ï¼Œä½†è¿‡åŽ»å¤§å¤šç ”ç©¶ä¸»è¦é›†ä¸­åœ¨é’›é’‰çš„稳定性方é¢ï¼Œè€Œè¿‘å¹´æ¥ä¸é”ˆé’¢é’‰ä½œä¸ºä¸€ç§æ–°ææ–™å› å…¶è‡ªèº«å¼ºåº¦è¾ƒå¥½ä¸æ˜“æŠ˜æ–­ï¼Œå¼€å§‹é€æ¸è¢«åº”用于临床。我科特选择20例ä¸é”ˆé’¢ç§æ¤é’‰æ”¯æŠ—患者就其施力时间进行研究,以期获得更好的临床稳定性。

 1ææ–™å’Œæ–¹æ³•

 1.1患者选择åŠå…¶åˆ†ç»„:选择2008å¹´1月~2010å¹´1月在我院进行错牙åˆç•¸å½¢æ²»ç–—的患者20例(ç”·10例,女10例),年龄16~18å²ï¼Œç”·å¥³æ‚£è€…按加载时间ä¸åŒè¢«å¹³åˆ†ä¸ºä¸¤ç»„,凿— æ˜Žæ˜¾ç¦å¿Œç—‡ï¼Œç¬¦åˆç§æ¤é’‰æ”¯æŠ—æ¤å…¥çš„适应è¯è¦æ±‚,共æ¤å…¥å¾®åž‹ç§æ¤é’‰40æžš ......